EE-1: Beginners' Electrical design course






Course Description:

This first level design course is intended to prepare the target persons with the theoretical and practical electrical design concepts noting that these concepts are explored in the context of National Electrical Code NEC.

The target Persons:

New graduate engineers, under graduate engineering students, electrical technician.

Skills Development:

On completion of this course the target person will be able to:

  • Understand electrical design basics.
  • Recognize all types of electrical symbols, drawings, design stages, buildings, codes, terminologies, loads and Major electrical equipments.
  • Create excellent knowledge base for next Level of electrical design course.


Course outline:

 

1- Introduction


2- Electrical symbols


3- Electrical Abbreviations


4- General basics of electricity:

4.1- Basic circuits 

4.2-  Electrical Systems Configurations

 

5- SI units system


6- Ranges of Voltage- Part One\ Part Two , 


7- Important formulas & Unit Conversion Tables

 

8- General overview of Generation, transmission & distribution stages of electricity.

 

9- Basic electrical definitions & terminology

 

10- Important electrical Terms- Part One

 

11- Major Types of buildings:

 

11.1-  Industrial buildings (Part-1)(Part-2)(Part-3)

11.2 Commercial buildings (Part-1)(Part-2)(Part-3)
(Part-4) (Part-5) (Part-6) (Part-7) (Part-8)

11.3 Health Care Facilities (Part-1) (Part-2) (Part-3)
(Part-4) (Part-5) (Part-6)

 

12- Electrical Load Classification and Types : (Part One) (Part Two) (Part Three

12.1- Lighting load (Part Four) (Part Five) (Part Six) (Part Seven) (Part Eight) (Part Nine)

12.2- Appliances loads


12.3- Electric Power loads:

12.3.1- HVAC load (Part One) (Part Two) (Part Three) (Part Four) (Part Five) (Part Six) (Part Seven)

12.3.2-  Elevator loads (Part One) (Part Two) (Part Three) (Part Four) (Part Five) (Part Six) (Part Seven) (Part Eight) (Part Nine) (Part Ten) (Part Eleven) (Part Twelve)


12.3.3-Motor and  Pump loads (Part One) (Part Two) (Part Three) (Part Four) (Part Five) (Part Six) (Part Seven) (Part Eight) (Part Nine) (Part Ten)

 


 

13- General overview of Electrical drawings types:

·  Design drawings

·  Construction drawings

·  Shop drawings (Part One) (Part Two)

·  Record drawings

·  Composite drawings

·  As built drawings

 

14- General overview of Electrical design stages:

·  Concept Design Phase

·  Preliminary Design Phase

·  Developed Design Phase

·  Detailed Design Phase

 

15- Construction Design Phase.

16- Electrical Design Criteria





15 comments:

  1. Hi Eng.Ali ,
    Please complete the remainig points of this topic >> Thanks

    ReplyDelete
  2. to Ahmad Shal,

    Hi Eng. Ahmad. I will do this very soon, just keep following. thanks

    ReplyDelete
  3. really great effort god bless you

    ReplyDelete
  4. بشمهندس هو جزء الرسومات مقفول ليه ؟؟

    ReplyDelete
    Replies
    1. the drawings types part is activated now, just click on the link.

      Delete
  5. Hi, excellent effort and electrical technology in single site ....

    ReplyDelete
  6. Helloo sir , Please guide me I need to design a electrical system of an commercial building having 2 basements & 8 floors.
    Please tell me how to proceed further.

    ReplyDelete
  7. eng ali
    i need password urgently

    ReplyDelete
  8. Hi Ali ,

    Thanks for This Information

    ReplyDelete
  9. THANK YOU SO MUCH, SIR! IT IS VERY USEFUL TO ME!

    ReplyDelete
  10. That is really awesome, thank you so much.

    ReplyDelete
  11. i want to attend this course where can i find it in south africa.

    ReplyDelete
  12. Brilliant Website with loads of Helping Material. JazakAllah Sir

    ReplyDelete