Electrical & Control System and Moving Walkways



I indicated in a previous Topic” Escalators Basic Components - Part One “that Escalators Basic components are as follows:
  1.  Landing Platforms.
  2. Truss.
  3. Tracks.
  4. Steps.
  5. Handrail.
  6. Escalator Exterior (Balustrade).
  7. Drive system.
  8. Auto-Lubrication System.
  9. Braking system.
  10. Safety devices.
  11. Electrical & Control Systems.

And I explained the first six items in this previous topic. Also, I explained the items from seventh to tenth in the previous topic “Escalators Basic Components – Part Two”.


Today, I will explain the last item; Electrical & Control Systems, also I will explain the Moving walkways as it is one of the transportation systems used in buildings.


Eleventh: Electrical & Control system


1- Escalator Motor

The escalator motor is typically an AC direct-on-line flange mounted unit, directly and/or flexibly coupled to the reduction gear. The motor is usually protected by thermal and electro-magnetic overload devices as well as thermistors in the motor winding. The motor operation is controlled by the main controller.


2- Main Controller


2.1 In Earlier Escalator Systems 


As I mentioned before, in earlier escalator systems it was common to use Conventional electromechanical starting systems, which include the following methods:
  1. Full voltage Wye Start/Delta Run connection starting.
  2. Part-winding starting.
  3. Reduced voltage starting.
  4. Autotransformer starting. 

These Conventional starting methods were used along with relay logic to control the starting method for the drive motor(s).

2.2 In Modern Escalators 


  • But in modern escalators, the main controller will use a soft start controller or a variable frequency drive along with a Programmable Logic Controller (PLC) to control and monitor the status of the escalator. The PLC may also be capable of communicating via an Ethernet to permit remote monitoring of the system. Modern escalator controllers incorporate an electronic fault diagnostic system. 
  • This fault diagnostic system is capable of logging statistical data on the operation of the escalator and includes memory to store escalator faults causing shut down. The escalator controller and fault diagnostic also includes an English language clear text display to allow immediate identification of the cause of a shutdown. The display is located within the inner decking at the upper end of the escalator. 
  • The display system normally provides a minimum of 2 lines of 20 characters for displaying programmable messages and fault conditions. Operation of the fault diagnostic system is possible at the display point via menus and keypads adjacent to or contained as part of the display system. 
  • The escalator controller and fault diagnostic system may include a text display to allow immediate identification of the cause of a shutdown. The controller itself could be located within the inner decking of the upper end of the escalator as well as the equipment machine room. Through the use of a keypad and the display, the technician is provided the ability to display programmable messages and fault conditions. Operation of the fault diagnostic system is possible at the display point by the use of menus and keypads adjacent to or contained as part of the display system. 


2.3 Escalator Controller Components 


Escalator Controller Components

a- A Circuit Breaker is a device designed to open and close a circuit by non-automatic means and to open the circuit automatically on a predetermined over-current. This is usually mounted near the control cabinet with accessibility of its red color handle or trip breaker. When opened, it isolates most electrical controls inside the controller.

b- Line Fuses are in line with each leg of the three-phase 480 VAC power supply located inside the controller or in a separate box. It is used as an over-current protection device, which has a similar function as the circuit breaker but normally used as a short circuit protection (catastrophic failure).

Typically, these fuses are of a time-delay category, capable of handling the initial in-rush current when the equipment is energized.

c- A Step down Transformer is used to step down voltages normally from 480vac to 120vac or other low ac voltages that may be used for controls and demarcation lighting.

d- A Motor Starter, when energized, its main contacts will provide power to the motor, and its auxiliary contacts may provide power to other control circuits. Typically, a dual contactor Motor starter is used where one starter controls the motor in the up direction and the other starter is responsible for the down direction. It may also be, one starter for each motors’ direction on two motors for dual drive or three for tri-motor drive escalator. Ideally, these contactors will be equipped with a mechanical interlock which would aid in preventing a phase-to-phase electrical short. Soft start starters are widely used in the modern escalators.

e- Brake Energizing Relay for the Main Drive Shaft, when energized, its contacts will provide power to the brake coil thereby disengaging the fail-safe brake for the motor to turn. When de-energized, the tension of the brake spring(s) will mechanically apply the brake capable of stopping a down running escalator with brake rated load.

f- Overload Protection – is normally a bi-metal normally closed contact that senses the heaters in line with the 480VAC power supply and the motor leads. When an overcurrent occurs, the heaters will transfer heat to the bi-metal contacts to open and disconnect the motor contactor coil thereby opening the contactors for the motor. Solid state versions use the same detection method but will provide low voltage protection to the control circuit thereby shutting down the power circuit as well as the control circuit.

Overload protection is the result of a device that operates on excessive current, but not necessarily on a short circuit to cause the interruption of current flow to the electric motor. Overload protection is not meant to protect the system from direct shorts, but rather to provide protection from excessive mechanical overload of the motor or to disable a motor which has overheated due to bearing or winding failure.

g- A Fault Indicating Device is part of the controller that operates to visually indicate the actuation of a safety device causing the escalator to shut down. It has an indication that remains until manually canceled or reset by the maintenance person or by the Station Agent/Manager. Indicating lamps are of a neon type or LED used to display unit malfunction or any activated safety devices.

h- A PLC or programmable logic controller, or programmable controller, is a digital computer used for automation of electromechanical processes, such as control of the drive machine, handrail speed, motor speed, motor frequency and voltage input as well as the monitoring of all safety devices. 

programmable controller

i- A Soft Start Controller is a solid state AC drive which controls the speed of AC motors by controlling the frequency and voltage of the power supplied to the motor.

An inverter provides the controlled power, and in most cases, the AC drive includes a rectifier so that DC power for the inverter can be provided from the main AC power. AC drives are also called variable-frequency drives, frequency inverters, or inverters. The speed of an AC motor is determined by the cycle number of alternating current it receives at each second and by the number of poles in the motor.

Since the number of poles of most industrial motors is fixed, the speed is more easily controlled by controlling the frequency.


3- Escalator Control Cabinets


3.1 Main Electrical & Control Cabinet 



Usually,The Main Disconnect Switch, motor protection and control devices are typically installed in an electrical cabinet positioned in the upper machinery well-way of the escalator. The cabinet will typically correspond to NEMA 3, ANSI/ASME standards by the escalator manufacturer comprising a steel enclosure with all required relays, automatic circuit breaker, and terminals completely wired for the escalator control. Fault annunciation is generally provided to identify activation of specific escalator safety devices.



3.2 Landings Control Station 

Landings Control Station
  • A control station at both upper and lower landings is provided which includes a key-actuated directional starting safety switch and a key actuated stop switch. 
  • The control station is located in the newel end skirt deck at the ends of the balustrades. 
  • A Code compliant emergency stop station is provided at each end of the escalator. The emergency stop is located in accordance with governing Code requirements and is covered by a transparent cover and alarm. 
  • Starting of the escalator in normal continuous operation mode shall only be possible using a dedicated key switch at upper and lower ends. (Some units have key switches at one end only.) 


3.3 Maintenance Control Station
Maintenance Control Station

Each escalator is provided with a pendant-style hand station to operate the escalator during maintenance or service work. Plug-in connection points for the pendant handset are provided at both ends of the escalator within the truss enclosure beneath the landing plates.

The handset includes continuous pressure push buttons to operate the escalator in either direction. A maintenance stop button is included. When plugged into the receptacle, there should be no means of operating or permitting the escalator to run other than through the use of the handset.


4- Escalator Electrical Lighting


4.1 Balustrade Lights 

The entire length of the escalator between the interior balustrade panels is illuminated by continuous fluorescent lighting called the Balustrade Lights. Only the steps and the side sections up to the skirt panels require light so that escalator passengers can see where they’re walking without having bright lights shine in their faces.

An emergency circuit will light every other lamp section on one balustrade in case of a power outage.



4.2 Comb Lights 

Comb Lights 

The Comb Lights illuminate the area where the comb-fingers meet the steps. They are located in the end skirts above the upper newel and lower newel comb-fingers. These lights are also on the lighting emergency circuit.



4.3 Maintenance Lights 

Maintenance & Step Demarcation Lights
  • Areas inside the upper truss, the lower truss, and the machine rooms are illuminated by Maintenance lights. 
  • Light switches next to each light turn them off and on. 
  • These lights are on the emergency circuit and will work if the escalator breaks down. 
  • No special procedure should be necessary for changing these lamps. 



4.4 Step Demarcation Lights
Gaps between steps at the upper and lower newels are lighted by green fluorescent tubes below the steps. These Step Demarcation Lights shine between steps to makes it easier and safer for passengers stepping on and off of the escalator. Demarcation Lights are on the emergency circuit.



4.5 Direction Indicators 

Direction Indicators

A red and a green light mounted on the right side of each newel indicate the escalator direction of travel when approaching the steps. A rider will usually want to enter the newel with the lighted green indicator and avoid the lighted red indicator. Each of these lights is made up of LED clusters and can be replaced after taking off the faceplate and the indicator box cover. By removing the retaining nuts on the back side of the plate, either lens can be replaced. The red light should be replaced in the top position.



5- Heating Systems and Controls 


5.1 Heater Operation
Heating elements are located in the upper, lower, and incline sections of each escalator installed from the entrance to the mezzanine levels. Their design purpose is to prevent ice from forming on the steps.


5.2 Heater Elements
  • These heaters are 2000 watt, 480 volt, single-phase tubular electrical elements that are controlled by a thermostat that is adjustable from 30°F to 110°F. 
  • To replace a heating element, it is necessary to first remove four step sections. Move the missing step section over the heater to be removed and disconnect the conduit box cover. 
  • Disconnect the heater wiring and conduit. 
  • It will be a lot easier to replace an element if the wires are tagged before they are disconnected. 

5.3 Heater Thermostatic Controls
The thermostat can be removed after taking out two steps and positioning the missing step section over the control. Turn the heater disconnect switch off before removing the box cover. Disconnect the wires and tag them for easy re-connection.


Moving Walkway


Moving Walkway

A moving walkway sometimes called Travelator, Horizontal Escalator is a slow moving conveyor mechanism that transports people, across a horizontal or inclined plane, over a short to medium distance. Moving walkways can be used by standing or walking on them. They are often installed in pairs, one for each direction.

Moving walkways, usually found in airports, are designed to move people over long distances, usually between different terminals. Moving walkways are similar to an escalator. The only difference is that the steps lay flat, like a conveyor belt. Passengers are able to move from gate to gate or from one baggage area to the next. Moving walkways, like elevators and escalators, offer a smooth and convenient ride for people while providing outstanding energy efficiency for commercial building operators.


Types of Moving walkways


1-According To Inclination Angle 


Horizontal and Inclined Moving Walkways
a- Zero degrees inclination “Horizontal” Moving Walkways.

b- Up to 15 degrees inclination “Inclined” ” Moving Walkways.



2- According To the Flat Moving Surface 


Moving walkways have two basic styles according to the flat moving surface:

a- Pallet Type 

Pallet Type Moving walkways

A continuous series of flat metal plates mesh together to form a walkway. Most have a metal surface, though some models have a rubber surface for extra traction.

b- Moving Belt 

Moving Belt Moving Walkway

These are generally built with mesh metal belts or rubber walking surfaces over metal rollers. The walking surface may have a solid feel or a "bouncy" feel.

Both types of moving walkway have a grooved surface to mesh with comb plates at the ends. Also, all moving walkways are built with moving handrails similar to those on escalators.

3- According To the Speed 


Moving walkways have two basic styles according to the flat moving surface:

a- Slow- speed Standard type 


The speed of these walkways is determined by the need for safety upon entry and exit, which generally limits it to approximately half normal walking speed, or 30–40m/min. The slow speed of the walkway causes impatience, and passengers often walk on the walkway itself or on the adjacent floor rather use the slower walkway.


b- High-speed walkways 

High-speed walkways

Using the high-speed walkway is like using any other moving walkway, except that for safety there are special procedures to follow when joining or leaving.

On entering, there is a 10 m acceleration zone where the "ground" is a series of metal rollers. Riders stand still with both feet on these rollers and use one hand to hold the handrail and let it pull them so that they glide over the rollers. The idea is to accelerate the riders so that they will be traveling fast enough to step onto the moving walkway belt. Riders who try to walk on these rollers are at significant risk of falling over.

At the exit, the same technique is used to decelerate the riders. Users step on to a series of rollers which decelerate them slowly, rather than the abrupt halt which would otherwise take place.



Moving walkways basic components: 

Moving walkways basic components

The moving walkways are identical to escalators in the basic components of their construction, but they differ in the following:
  • Moving walkways may run horizontally or on an incline of up to 15 degrees. 
  • The flat moving surface of the moving walkways may consist of a continuous rubber belt or a series of jointed treads. 
Moving walkways basic components
The main basic components of the moving walkways will be as follows: 

  1. Truss.
  2. Tracks.
  3. Drive motor.
  4. Gear box.
  5. Service track.
  6. Handrail drive wheels.
  7. Pallet chain sprockets.
  8. Pallets.
  9. Pallets chain.
  10. Handrail.
  11. Lower reversing station.
  12. Balustrade panels.
  13. Decks.
  14. Newel ends.
  15. Skirts.
  16. Access cover.
  17. Comb plates.
  18. Front plates.
  19. Controller.

Moving walkways Safety Devices: 


The safety devices that be included in most of the moving walkways are as tabulated in the below image.

 



In the next Topic, I will explain the Electrical Pumps and Motors. So, please keep following.



Note: these topics about Escalators in this course EE-1: Beginner's electrical design course is an introduction only for beginners to know general basic information about Escalators as a type of Power loads. But in other levels of our electrical design courses, we will show and explain in detail the Escalators Loads Estimation calculations.



Course HVAC-1: An Introduction to Heating, Ventilation and Air Conditioning (HVAC) Systems


Course Description:


This course is intended to prepare the target persons with the ability to understand and recognize different types, components and accessories of HVAC systems.

The target Persons:


Design engineers, new graduate engineers, under graduate engineering students, site field engineers, maintenance engineers and technicians.

Skills Development:


On completion of this course the target person will be able to:

  • Understand the technology, concepts and terminology in the design of HVAC systems.
  • Recognize different types, components and accessories of HVAC systems. 
  • Specify correctly any type of HVAC systems. 

Course Outline 

B- Types of heating systems.
B.1 Central Heating System.
- Furnace.
- Hot water & steam boiler.
- Heat Pump.
- In Floor or Under Floor Heating.
B.2 Local heating Systems.










Escalators Basic Components – Part Two


I indicated in the previous Topic” Escalators Basic Components - Part One “ that Escalators Basic components are as follows: 
  1. Landing Platforms.
  2. Truss.
  3. Tracks.
  4. Steps.
  5. Handrail.
  6. Escalator Exterior (Balustrade).
  7. Drive system.
  8. Auto-Lubrication System.
  9. Braking system.
  10. Safety devices.
  11. Electrical & Control Systems.
And I explained the first six items in this previous topic. Today, I will explain other Escalators Basic Components as follows.


Seventh: Drive Systems
Drive Systems

An escalator drive system includes the following components:
  1. Drive Machine and Gear Reducer.
  2. The Step Drive System.
  3. The Handrail Drive System. 

The variation on how these two systems are combined is dependent upon the type of escalator. The Drive Machine used to drive the pinion gear or the main drive chain may directly or indirectly drive the Handrail Drive System.


1- Drive Machine and Gear Reducer
Drive Machine and Gear Reducer

A- Drive Machine 


The Drive machine together with the gear reducer provides the torque to drive the step band at a constant speed.

The drive machine motor is typically a three-phase AC direct-on-line flange mounted unit. It is either directly or flexibly coupled to the reduction gear. The motor is usually protected by thermal and/or electro-magnetic overload devices as well as thermistors in the motor winding.

A.1 Types of Drive Machines:


There are three types of drive machines:
  1. External Drive.
  2. Internal Drive.
  3. Modular Drive.

A.1.1 External Drive

External Drive

Machine is remotely located outside the truss in a different room/space or in the upper pit area. The Drive machine is located outside the truss.

The main drive machine is located in the upper pit area or in a separate machine room located below the upper section of the escalator. An external drive located in the upper pit area may employ a direct motor to gearbox drive, or a motor to gear reducer with a chain drive. An external drive escalator with the drive unit located within a machine room beneath the upper landing will normally employ a motor/gearbox with a chain drive extending to the upper landing.


A.1.2 Internal Drive

Internal Drive
 
Machine may be located at the upper landing inside the truss between the step bands or at the top pit, and will employ a motor to gearbox drive with a direct drive axle connection. A separate dual drive machine within the step band is not uncommon with one machine used to directly drive the step chains located a few feet below the upper incline and one above the lower incline. Internal escalator drive machines may be one, two, or three drive. A dual or three-machine may power the same main drive shaft or pinion shaft at the upper incline. Some internal drive escalators are equipped with either dual or three drive machines all inside the step band or step-belt.


A.1.3 Modular Drive
 

Machine is located within the incline of the truss between the step bands. The main drive is located within the incline of the truss within the step band. The motor may be directly connected to the gearbox or it may transfer power through a belt drive. The gearbox will have a direct connection to the drive axle. A modular escalator may have a single drive or a multiple drive depending on the overall length of the escalator.



A.2 Drive Machine Starting Methods 


There are two common methods for drive machine starting as follows:

A.2.1 Conventional electromechanical starting systems, which include the following methods:
  1. Full voltage Wye Start/Delta Run connection starting.
  2. Part-winding starting.
  3. Reduced voltage starting.
  4. Auto-transformer starting. 

Disadvantages of conventional electromechanical starting systems are as follows:
  • It requires a higher starting and running amperage. 
  • It causes some wear and tear on the equipment with startups. The sudden jerk of the startup sequence was a shock to all the moving parts. 


A.2.2 Solid-state soft-start controllers,

Solid-state soft-start controllers

The soft start controller is a solid state AC drive which controls the speed of AC motors by controlling the frequency and voltage of the power supplied to the motor.

It has the following advantages:
  • It can adjust the motor power to the number of riders using the escalator while maintaining normal speed. 
  • It can reduce electricity use by a significant amount. 
  • It allows for gradual smooth starting of three-phase squirrel cage motors. 
  • It allow precise adjustment of motor starting torque, eliminating mechanical shocks which led to premature bearing wear, shaft and belt breakage, increased maintenance time, and costly production stoppages. 


B- The Main Drive Gear (Gear Reducer)

The Main Drive Gear (Gear Reducer)

The Main Drive Gear or gear reducer assembly may be a single-stage type gear reducer. This is an enclosed, mechanical device that takes the drive motor torque and transmits this torque to the bull gear through a gearbox shaft (pinion) or the main drive chain. The gear reducer assembly contains a steel worm gear that is coupled or directly sleeved onto the motor shaft and it meshes with the pinion (bronze) gear.


2- The Step Drive System
Step Drive System
 
The step motion is achieved by a direct step assembly connection to the step chains.

Two-step chains; one for each side of the escalator are directly coupled to the Main Drive axle, the bull gear shaft, through the step chain sprockets. The step chain form a loop for the length of the truss, from the step chain sprockets at the upper end down to the tension carriage gear or turnaround (depending on the manufacturer) at the lower end or the lower reversing station.

Step Drive System

The Main Drive Axle is driven by the motor and reducer assembly. Sprockets or bull gears (depending on the manufacturer). On both ends of the Main Drive Axle transfer power the Step Drive System. These sprockets or bull gears drive two step chains, one each for the right and left sides of the escalator, which are connected at the lower end of the escalator to the step chain sprockets of the Tension Carriage.

The Step Chains are endless links connected with link pins to make a complete loop and are attached to an axle on each side of the steps forming a loop which runs for the length of the truss from the upper Main Drive Axle to the lower Tension or Turnaround.



Circle Tracks (Crab Tracks) 

Circle Tracks (Crab Tracks) 

The Circle Tracks provide smooth step travel at the end of the tracks. The Chain Wheel is used to maintain proper tracking of the step chain. Most of the outer circle tracks have access windows for easy step removal.


3- Handrail Drive System 

Handrail Drive System 

The handrail drive moves the handrail along the handrail tracking system through traction on the V-shaped handrail underside. The handrail drives consists of the following:
  1. The handrail drive and idler sheaves. 
  2. Handrail drive sprockets. 
  3. Handrail drive chains. 
  4. Handrail Take-Up Devices. 
  5. The Handrail Support Rollers. 

A- The Handrail Drive and Idler Sheaves 

They are V grooved sheaves located in the upper newel ends of the escalator. Idler sheaves are V grooved sheaves located in the lower newel ends of the escalator. The handrail drive sheave drives the handrail in its journey around the escalator while the idler sheave reverses the direction of the handrail at the lower end.


B- The Handrail Drive Chain Sprockets


They are located on the handrail drive sheave and the outboard end of the bull gear shaft. Handrail drive sprockets are linked by the handrail drive chain and provide a direct link between the bull gear and handrail drive sheave.


C- The Handrail Drive Chains


They are double stranded chains and are the mechanical link between the dual toothed drive chain sprockets. The drive chain sprockets and handrail drive chain coming to transfer power from the bull gear shaft to the handrail drive sheave. The Handrail drive chain has an adjustable take-up sprocket to keep the drive chain snug. The handrail drive chain receives lubrication from an enclosed bath system.


D- The Handrail Take-Up Devices


They are located directly downhill from the handrail drive sheaves. The handrail take-up devices remove slack in the handrail to provide the proper amount of slack in the handrail required to drive the handrail. The short handrail take-up device can be adjusted to remove slack from the handrail. The long handrail take-up device can pivot from the center and be adjusted at the uphill end to remove slack from the handrail. The long handrail take-up device is always required. 


E- The Handrail Support Rollers

They are located at various intervals down the incline. Their function is as follows:
  • They support the handrail and protect it from coming into contact with the track brackets or any other truss components which may damage the handrail. 
  • They help provide the correct loop of slack in the handrail at the lower end which proves the traction to drive the handrail. 


Eighth: Auto-Lubrication System 

 Auto-Lubrication System 

The escalators have an Automatic Lubrication System that supplies oil to lubricate the main drive chain, step chain, and the handrail drive chains. Oil flow rate is adjustable by setting the automatic timer control “off” and “on” periods to supply more or less lubrication.

The Automatic Lubricator has a gage to show oil reservoir level. The Lubrication Timer can be programmed for any time mode but, is pre-set for a 20 hour cycle. The system dispenses pre-determined amounts of oil to the distribution network which delivers this oil to the bearing points.

Note: The Auto Lubrication System does not supply grease to the drive system bearings. Drive bearing lubrication must be done manually. Bearings that need to be manually lubricated are the Main Drive Bearings, the Tension Carriage Bearings, the Motor Bearing, and the Handrail Drive bearings.

Additionally, the bearing surface of the Main Drive Shaft Brake, the Step Axle sleeve, the Step Wheel guide-shoe, and the Gear Box are manually lubricated.



Ninth: Braking Systems
Braking Systems
 
The braking systems on an escalator utilize three different braking methods as follows:
  1. The Machine Brake.
  2. The drive shaft brake system.
  3. The Main Drive Shaft Brake.

1- The Machine Brake 


It is an electromagnetically released, spring-applied, disk that is driven by a spline hub mounted to the extended worm input shaft of the gear-reducer. This type of brake is referred to as a fail-safe brake. When the brake coil is de-energized, springs within the assembly press the armature against the disc, and slowly stop the escalator. If an emergency button is pushed, if any of the safety switches are opened, or if there is a loss of power, the coil will be de-energized and the machine brake will be engaged.

2- The drive shaft brake system


It is also known as the Step Chain Locking Device or the broken drive chain device. It is often referred to by this name when it is used for maintenance purposes to lock the drive system. In this case, the guide shoe is removed to allow the pawl to drop and engage the ratchet.

3- The Main Drive Shaft Brake


It uses a pawl that is welded onto one end of the main drive shaft to engage a ratchet wheel with brake linings on both faces. The brake lining wheel is sandwiched between the handrail 1st drive sprocket and the step chain sprocket.

A guide shoe lever is welded onto the opposite end of the main drive shaft. The guide shoe is normally supported by the drive chain and when the chain breaks, the shoe drops and turns the shaft. The drive shaft brake pawl moves into the ratchet wheel and stops the escalator when the guide shoe drops.



Tenth: Safety devices 


Safety devices

Escalator systems are provided with many safety devices that will automatically stop the escalator by cutting electrical power to the motor and applying the brake if a problem occurs. When a safety device stops the escalator, the problem must be corrected and the fault cleared before restarting the system.

If a safety device is tripped out, a corresponding safety relay (PLC Input/output) will drop out. This applies voltage to the latching circuit of that device. If any safety circuit control is tripped, the escalator will not operate and the tripped devices will do one of the following actions:
  • It will automatically reset when the fault is corrected. 
  • It will require resetting only the main safety reset button inside the controller. 
  • It will require that the individual controller circuit for that device must also be reset. 


Safety Devices Types:


there are so many safety devices included in the escalators as follows:

1- The Broken Drive Chain Device, or Step Chain Locking Device/Pawl Brake, is a ratchet- type device that prevents the escalator steps from sliding down from the weight of passengers if the drive chain breaks.



2- A Broken Step Chain Device (tension carriage) cuts power to the motor and applies the brake if the step chain breaks or if the step chain is loose.

 Broken Step Chain Device

3- A Skirt Obstruction Device cuts power to the motor and applies the brake if an object is wedged between the skirt panel and a step. This type of deflection will depress one of the plunger limit switches that are located behind the skirt panel at the upper and lower transitions and at intervals between.

 Skirt Obstruction Device
 
4- A Comb Step Impact Device cuts power to the motor and applies the brake if a jam occurs between the comb plate and a step.

 Comb Step Impact Device
 
5- A Step Level Device cuts power to the motor and applies the brake if either side of the step at the riser end is depressed downward more than 1/8” or, if the step chain axle is depressed downward more than 1/8”.

Step Level Device

6- A Missing Step Device cuts power to the motor and applies the brake if an opening is detected in the step band.

 Missing Step Device
 
7- The Broken Step Device is triggered if any of four roller lever limit switches are tripped. Two of the roller switches are located below the main drive and two are located below the tension carriage. When an out-of-place step trips the switch, power is cut to the motor and the brake coil will be de-energized.

Broken Step Device
 
8- A Step Up-Thrust Device is located at the transition from the incline to the flat section of the truss.

Step Up-Thrust Device
 
9- Handrail Entry Device is located at the handrail entry port of each newel section. This device will cut power to the motor and apply the brake if an object is wedged between the handrail and the rubber entry guard. Any caught object will depress two switches behind the handrail guard.

Handrail Entry Device

10- A Broken Handrail Device is located in the escalator incline section. The device consists of a hinged roller that is held up by handrail tension. If a handrail is stretched or broken, a limit switch is depressed by the roller bracket dropping. When the switch is pressed, it cuts power to the motor and applies the brake. The safety reset button in the controller must be pressed to restart the escalator.

Broken Handrail Device
 
11- The Handrail Speed Device is a 1000 RPM tachometer generator wheel that rolls on the handrail. The weight of the tachometer generator and wheel pivots on a bracket to hold the wheel against the handrail. Contact of the tachometer wheel on the moving handrail turns the generator, which outputs a voltage of 6.72 volts. If the handrail speed drops below 80% or increases more that 110% over this voltage, then power to the escalator motor is cut and the brake is applied.

Handrail Speed Device
 
12- A Reversal Stop Device immediately stops the escalator when the direction of an ascending escalator is reversed. This device is located just above the incline section of the escalator. It consists of a lever clamped to the middle handrail shaft which rotates in the direction of travel. If the shaft direction is reversed, the lever will rotate and trip the switch, cutting power to the motor and brake.

Reversal Stop Device
 
13- An Emergency Stop Button is provided at both the upper and lower landing of the escalator. This covered button allows anyone to stop the escalator immediately in the event of an emergency. Lifting the cover of the emergency stop button will cause an alarm to sound for five minutes or until the escalator is restarted. Pressing the button will stop the escalator immediately. The escalator can be restarted after releasing the button by using the normal start-up procedure.

 Emergency Stop Button
 
14- A Thermal Overload Relay is installed on the controller panel to protect the electrical drive motor from burning out due to escalator overload or a current overload. The relay can be reset by pressing the “Reset” button on the top of the Overload Relay.


15- MECHANICAL SAFETY DEVICES There are several mechanical safety devices that are used to stop and prevent movement of the escalator. These include locking bars, emergency brakes, and skirt brushes.

MECHANICAL SAFETY DEVICES
 

In the next Topic, I will continue explaining the Escalators Electrical & Control system and Moving Walkways. So, please keep following.


Note: these topics about Escalators in this course EE-1: Beginner's electrical design course is an introduction only for beginners to know general basic information about Escalators as a type of Power loads. But in other levels of our electrical design courses, we will show and explain in detail the Escalators Loads Estimation calculations.




Escalators Basic Components - Part One



I explained all the basic components for the traction elevators (Pull elevators) in the following previous Topics:

And I explained the basic components of the Hydraulic Elevators (Push Elevators) in the previous topic “Hydraulic Elevators Basic Components”.

Today, I will explain the Escalators Basic Components as follows.

You can review the following previous topics for more information and good following.


 

An escalator
is a moving staircase – a conveyor transport device for carrying people between floors of a building.

Escalators are powered by constant-speed alternating current motors and move at approximately 1–2 feet (0.30–0.61 m) per second. The maximum angle of inclination of an escalator to the horizontal floor level is 30 degrees with a standard rise up to about 60 feet (18 m). Modern escalators have single piece aluminum or steel steps that move on a system of tracks in a continuous loop.

Direction of movement (up or down) can be permanently the same, or be controlled by personnel according to the time of day, or automatically be controlled by whoever arrives first, whether at the bottom or at the top (the system is programmed so that the direction is not reversed while a passenger is on the escalator).

The benefits of escalators are many:
  • They have the capacity to move large numbers of people.
  • They can be placed in the same physical space as one might install a staircase. 
  • They have no waiting interval (except during very heavy traffic).
  • They can be used to guide people toward main exits or special exhibitsز
  • They may be weatherproofed for outdoor use. 
  • They can help in controlling the traffic flow of people For example, an escalator to an exit effectively discourages most people from using it as an entrance, and may reduce security concerns. 


Escalators Configurations:

Escalators have four typical configuration options:

1- Parallel 

Parallel Escalators 

Up and down escalators "side by side or separated by a distance," seen often in metro stations and multilevel motion picture theaters)

2- Crisscross
Crisscross Escalators 

(Minimizes structural space requirements by "stacking" escalators that go in one direction, frequently used in department stores or shopping centers)

3- Multiple parallel 

Multiple parallel Escalators

(two or more escalators together that travel in one direction next to one or two escalators in the same bank that travel in the other direction).

4- “Up” Escalator next to Staircase 

“Up” Escalator next to Staircase

It is preferred that staircases be located adjacent to the escalator if the escalator is the primary means of transport between floors.

Note: It may also be necessary to provide an elevator lift adjacent to an escalator for wheelchairs and disabled persons


Escalators Basic Components 

Escalators Basic Components 

The 
Escalator consists of the following components:
  1. Landing Platforms.
  2. Truss.
  3. Tracks.
  4. Steps.
  5. Handrail.
  6. Escalator Exterior (Balustrade).
  7. Drive system.
  8. Auto-Lubrication System.
  9. Braking system.
  10. Safety devices.
  11. Electrical & Control Systems.

First: Landing Platforms

Landing Platforms

These two platforms house the curved sections of the tracks, as well as the gears and motors that drive the stairs. The top platform contains the motor assembly and the main drive gear, while the bottom holds the step return idler sprockets. These sections also anchor the ends of the escalator truss.

In addition, the platforms contain a floor plate and a combplate. The floor plate provides a place for the passengers to stand before they step onto the moving stairs.

This plate is flush with the finished floor and is either hinged or removable to allow easy access to the machinery below. The combplate is the piece between the stationary floor plate and the moving step. It is so named because its edge has a series of cleats that resemble the teeth of a comb. These teeth mesh with matching cleats on the edges of the steps. This design is necessary to minimize the gap between the stair and the landing, which helps prevent objects from getting caught in the gap.


Major components of 
Landing Platforms are: 

  • Combplates also known as walk-on plates are an entrance and exit for the passengers to the steps. It provides mounting for the comb segments and combplate (comb impact) switch actuator. 
  • Comb Segments are replaceable sections, usually between 6” to 8” in width or maybe narrower, with teeth that mesh (comb) into the step treads. Comb segment may also be called a combplate by non-standard noun name. A left hand, a right hand, or a middle section comb segment can be identified by the pattern of the combs on their sides and by the width or number of combs. 
  • Access Covers used as an access to the pit area for inspection, maintenance, and repairs. The lower landing access cover plates provide access to the reversing station and step removal. The upper access cover plates may provide an access to the driving machine, bull gear, and sometimes the controller. 
  • Comb Lights are an optional safety device used to illuminate the area where steps and comb segments meet, mounted at the upper and lower landing above the comb segments. They are from a different power source that stays on always even if the unit is not running. 


Second: Truss
The escalator truss

The escalator truss
is the structural frame of the escalator and consists of three major areas:
  • The lower section, 
  • Incline section, 
  • Upper section. 

It is a hollow metal structure that bridges the lower and upper landings. It is composed of two side sections joined together with cross braces across the bottom and just below the top.

The ends of the truss are attached to the top and bottom landing platforms via steel or concrete supports. The truss carries all the straight track sections connecting the upper and lower sections. The structural steel truss members are designed to carry the entire load of the escalator equipment and the steel covering without shifting more than specified by the contract requirements. The entire structure is rigid enough to maintain close operating tolerances but will allow for building shift and vibration because of a built-in system of shift- plates and Teflon pads.



Third: Tracks 

Tracks  system    

The track system is built into the truss to guide the step chain, which continuously pulls the steps from the bottom platform and back to the top in an endless loop. There are actually two tracks:
  • One for the front wheels of the steps (called the step wheel track).
  • One for the back wheels of the steps (called the trailer-wheel track). 
The relative positions of these tracks cause the steps to form a staircase as they move out from under the combplate. Along the straight section of the truss, the tracks are at their maximum distance apart. This configuration forces the back of one step to be at a 90-degree angle relative to the step behind it. This right angle bends the steps into a shape resembling a staircase.

At the top and bottom of the escalator, the two tracks converge so that the front and back wheels of the steps are almost in a straight line. This causes the stairs to lay in a flat sheet-like arrangement, one after another, so they can easily travel around the bend in the curved section of track.

The tracks carry the steps down along the underside of the truss until they reach the bottom landing, where they pass through another curved section of track before exiting the bottom landing. At this point, the tracks separate and the steps once again assume a staircase configuration. This cycle is repeated continually as the steps are pulled from bottom to top and back to the bottom again.

Three major assemblies of the tracks are:
  • Upper.
  • Incline.
  • Lower.

The track assembly is bolted but not welded on the truss for easy removal. Sometimes they are mounted on boilerplate (support plate mounted against the truss) or curve plates at the upper and lower landing sections. The tracks are used to guide steps wheels and step chains in their travel around the escalator truss. They are curved at the upper and the lower end of the incline to allow smooth transition of steps from the form of stairs to a horizontal movement, or vice versa. The lower and top end tracks are formed semi-circles to contain the chains and the step rollers going around them.

Track assembly major components are:
Track assembly major components

a. Circle Tracks or Crab tracks (A) are located at the top and bottom pits. Most of the outer circle tracks have access windows for easy step removal. Some are mounted on a removable or replaceable curve plate. The Montgomery & Montgomery KONE escalators circle tracks at the lower reversing station are part of the “make-up track” that travels with the carriage. Circle tracks provide smooth step travel at the end of the tracks. The distance of the inside circle track from the carriage shaft of Westinghouse escalator is used to measure the wear of the step chain.

b. Beveled Track (B) provides smooth transition of chain wheels to and from the carriage sprockets. Beveled track eliminates the bumping effect of the chain wheels to the tracks, thus minimizing premature wear and damage to the wheels.

c. Chain Wheel, Upper Upthrust (hold down) Track (C) is used to hold down and guide chain wheels to and from the transition.

d. Chain Wheel, Upper Line Track (D). Used to support the chain wheels to/from the bull gear sprockets' top end through the incline area down to the carriage sprockets' top, or vice versa.

e. Step Wheel, Lower Upthrust Track (E). A few feet of track used to hold down and guide step wheels to and from the transition area.

f. Step Wheel, Lower Line Track or Flat Track (F) works in conjunction with the lower upthrust step wheel track. Flat track supports the step wheels in either ascending or descending through the incline.

g. Chain Wheel, Return Track (G) is used to support the chain wheels from the bull gear lower end to the carriage lower end, or vice versa.

h. Step Wheel, Return Track (H). Slightly above the chain wheel return track at the incline section of the non-passenger side. Step wheel return track is used to position the step treads to run in parallel with the chain wheel return track.


Forth: Steps 


The steps are solid, one piece, die-cast aluminum or steel. Yellow demarcation lines may be added to clearly indicate their edges.

The steps are linked by a continuous metal chain that forms a closed loop. The front and back edges of the steps are each connected to two wheels. The rear wheels are set further apart to fit into the back track and the front wheels have shorter axles to fit into the narrower front track. As described above, the position of the tracks controls the orientation of the steps.


Steps Major Components 

Steps Major Components 

  • The Step Plate (Tread) is the surface area of the step people step on. The step plate is usually made of an aluminum plate with longitudinal cleats or grooves that run through the combs and provide secure footing. 
  • The Step Riser is the vertical cleat cast into the front of a step, designed to pass between the cleats of adjacent step, thus creating a combing action with minimum clearance for safety. 
  • The Demarcations are yellow strips or may be in bold color around the step tread but mostly located at the front and at the rear ends of the tread. They are used to visually locate the step separation and visual contrast between the steps and the combs. 
  • Frame/Yoke - main support for riser, step tread, and step wheels 
  • Trail Wheels are used to guide the step and support its load on the track and prevent it from being out of plane. 
  • Step Hook normally attached to the end of the yoke by the step wheel used to activate the step up thrust safety device when the steps are not on their plane of travel at the top and bottom inclines. 

Note: The length of the step is measured from both ends of the step tread (front and rear) and the width is from both sides of the step.


Sixth: Handrail 

Handrail Assembly

The Handrail provides a convenient handhold for passengers while they are riding the escalator. In an escalator, the handrail is pulled along its track by a chain that is connected to the main drive gear by a series of pulleys.

The Handrail is constructed of four distinct sections:

Handrail Components
  • At the center of the handrail is a "slider “also known as a "glider ply," which is a layer of a cotton or synthetic textile. The purpose of the slider layer is to allow the handrail to move smoothly along its track. 
  • The next layer, known as the “tension member” consists of either steel cable or flat steel tape and provides the handrail with tensile strength and flexibility. 
  • On top of the tension member are the inner construction components which are made of chemically treated rubber designed to prevent the layers from separating. 
  • Finally, the outer layer, the only part that passengers actually see is the cover which is a blend of synthetic polymers and rubber, this cover is designed to resist degradation from environmental conditions, mechanical wear and tear, and human vandalism. 


Seventh: Escalator Exterior (Balustrade)

Escalator Exterior (Balustrade)

The Balustrade consists of the handrail and the exterior supporting structure of the escalator. It is the escalator exterior components extending above the steps and it supports the handrail. It is either designed as Interior Low-deck or Interior High-deck.

The balustrade may also refer to the individual interior panels, skirt panels, and deck covers of the escalator. Each interior balustrade panel section is individually removable to allow easy access to the escalator interior for cleaning, maintenance, and component replacement.

 Escalator Exterior (Balustrade) Components:

1. Interior Low-deck
has interior or side panels that are usually glass panels that support the handrail base.

2. Interior High-deck is the side panel and is usually aluminum or steel alloy sheets, sometimes called solid panels. The major components of interior high-deck are:

a. Skirt Panel - commonly called a “Skirt." It is the interior covering of the balustrade located alongside the steps. It houses the actuator for the skirt safety switch. Side Safety Brushes are installed slightly above the step level on the skirt panel to provide passenger safety between the side of the steps and the skirt.

b. Interior Panel - commonly called “side panel" by mechanics. The central point of the balustrade that supports the handrail base and sets the proper elevation for handrails on a glass balustrade. It provides access to the handrail; driver, idlers, sheaves, skirt switches in interior high-deck balustrades, and various components.

c. Handrail Stand - the handrail tracks or guides located above the side panels or maybe the upper deck.

d. High-deck Interior - the top most, inner part of the balustrade that supports the handrail track or guide.

e. High-deck Exterior - top most outer covering of the balustrade outside and above the side panels. Supports the outer side of the handrail guide. If the outer edge of the deck is greater than 12 inches from centerline of the handrail, an anti-slide device or sometimes called baggage stops (like a hockey puck) must be installed.

f. Low-deck Interior or Inner Decks - the inner covering of the balustrade located between the glass panels and the skirts. Provide access to the handrail drivers and skirt switches in interior low-deck balustrades.

g. Low-deck Exterior or Outer Decks - the outer covering of the balustrade located outside the glass panels.

h. Exterior Panel is an outer covering below the high-deck exterior.

i. Newel - is the balustrade termination at the upper and the lower landing of the escalator in a semi-circle shape. It normally houses the following switches; emergency stop, on/off, up/down or directional indicator lighting, Entry to and exit from the escalator normally occurs at one of the newels and several important features are conveniently located at each.

j. Newel Base or Front Plates - supports the newel stand and it may house the Handrail Inlet (Guard) Safety Device.

k. Emergency Stop Button is the most important feature at each Newel. The Emergency Buttons are located so that anyone can stop the escalator if there is a need. These switches have a lift cover that will sound an audible alarm when lifted. When either button is pushed, power to the electrical drive motor is shut off and the escalator brake is applied.

l. Key Operated Switches are located on each Newel and they are used to control the “ON” and “OFF” operation and the direction of escalator travel. These switches are intended for the use of authorized personnel only.



In the next Topic, I will continue explaining the Escalators Basic Components . So, please keep following.



Note: these topics about Escalators in this course EE-1: Beginner's electrical design course is an introduction only for beginners to know general basic information about Escalators as a type of Power loads. But in other levels of our electrical design courses, we will show and explain in detail the Escalators Loads Estimation calculations.