1- Cummins Power Company
Application Engineering – Liquid Cooled Genset Application Manual
Chapter 1 – Introduction gives an overview of the content of this manual, important safety information and references to other application manuals.
Chapter 2 – Preliminary Design describes the initial considerations for the power generation project. Equipment and installation requirements vary depending on the situation and intended use of the power generation. Guidelines for generator power ratings lead to the appropriate choice of duty according to the load requirements, with information on the considerations that need to be made in the choice of location.
Chapter 3 – Electrical Load Impact on Generator Sizing explains various load types, their characteristics and their impact on generator set size, operation and equipment choices. The chapter helps the reader to understand how generator performance is affected by the applied load and how the load may be affected by the generator characteristics. The importance of the sequence of load connection is explained and illustrated.
Chapter 4 – Equipment Selection describes the fundamental parts of a generator set and related equipment; their functions, inter-relationships and criteria for choices. The chapter describes the construction and functions of the brushless alternator and the effect of choice of excitation systems on load acceptance and short-circuit performance. Engine governing, starting systems, controls and a range of accessories are discussed.
Chapter 5 – Electrical Design details the electrical installation design of the generator in various application scenarios; i.e., single generator set installations or paralleling applications, related electrical systems and their interface with the facility and load. Topics discussed include, electrical connections, circuit breakers and disconnectors, choosing a generator transformer, voltage drop calculations, leading and lagging power factor loads, and protection coordination.
Chapter 6 – Mechanical Design explains installation design and related mechanical systems and their interface with the facility. Topics include foundation and mounting, vibration isolation, exhaust, cooling, ventilation and fuel systems; noise reduction, fire protection and equipment room layout. The chapter also contains illustrated examples of correct ventilation and exhaust system layout in order to avoid recirculation and promote efficient cooling.
Chapter 7 – Appendices contains an overview of GenSize – the Cummins Power Generation sizing software application and PowerSuite contents. Also included is a discussion of reduced voltage motor starting techniques and useful references to world voltage standards, formulae, codes and standards and a glossary of terms.
Chapter 8 – Checklists contains checklists for an overall project, installation of open and enclosed generator sets, pre-start-up and start-up stages. These lists help to ensure that a comprehensive project portfolio is established and that every stage in the project is completed.
to download the complete guide, please click Here.
2- Caterpillar Inc.
Engine Application and Installation Guide
- Air Intake Systems
- Alignment
- Cooling Systems
- Diesel Engine Control Systems
- Diesel Fuels and Diesel Fuel Systems
- EMCP 3.1, 3.2, 3.3 Generator Set Control
- EP Applications, Engine and Generator Sizing
- Engine Room Ventilation
- Exhaust Systems
- Gas Control Systems and Ignition
- Gaseous Fuels
- Generator Systems
- Governors - Gas and Diesel
- Lubrication Systems
- Mounting
- Noise
- Starting Systems
- Uninterruptible Power Supply
- Vibration