DIALux Lighting Software Program
There are two Dialux Programs as follows:
- DIALux Main (Red Version)
- DIALux Light (Blue Version)
Today, I will explain the Dialux Light (Blue Version) as follows:
1-Run the program, you will get the first page , click next.
2- in this page, enter the Project name, room name, project description,
any project additional information, designer data and designer’s company data.
After finishing, click next.
3-in this page, enter the room geometry dimension,
reflection factors, maintenance factor, height of work plane and select the
luminaire type from the catalogs button.
4-in this page and after pressing catalogs button, select
one of the (3) options indicated as : dialux catalog, online catalogs,
luminaire files and my database
Press my database as an example.
5-in this page, select (*) to get all the luminaires which
installed by default with the program.
6-in this page, select the luminaire by pressing on its
name, then press apply button for confirm lumiaire type selection, than press
close button to return to program page step #4.
7-in this page, you will find the selected lumiaire data from step #6 is added to lumiaire
selection part, then select the luminaire mounting method, then enter the
suspension height and then press next button.
8-in this page, enter the planned illumination level
(lux), then press suggestion button which will show you luminaire arrangement
inside the room with estimated Lux for this arrangement.
You can change the arrangement of the suggested
luminaires and change their distance from the wall ,ceiling and from each other
in the horizontal and vertical arrangement part
You can also make rotation for luminaire from the
luminaire parameters part, then after you get suggested LUX near the planned
one , press calculate button
9-in this page, the luminaire distribution with lux
levels will be indicated, check that all the values are as the planned ones and
then press next.
10-in this page, select the output type and format of the
calculations results , you can print the output file or save it as a dialux
project file / PDF file , then pres next to finish the dialux program
calculations for the assigned room.
11-in this page, you can select either finishing the
program by pressing finish button or activate the empty square box for doing
calculations for other rooms.
To Download Dialux Program- Latest Version, press on below Link
To Download Dialux English Manual- Latest Version, press on below Link
To Download all manufacturers’ catalogs/Plugins that work with Dialux Program, press below Link

Thanks.
ReplyDeletedear/ ganah
ReplyDeleteplease give me your opinion about the new shape of the site ,i redesign it on Links bases that just press the link and you will get the topic you want
waiting your opinion
thanks
Dear\eng.Ali
ReplyDeleteIam so sorry for the delay in reply but I see your comment only now. I actually liked the new shape of the site,it is more easier to search topics.
thanks a lot for the nice topic.
God bless you.
thanks eng.ganah for your consideration
ReplyDelete